Dariush Forouher wrote:
> >Try this one...
>
> You config doesn't work for me, but this does:
> S19.2E 11700 V 9750 t v W15 [E0 10 38 F0] W15 t
> S19.2E 99999 V 10600 t v W15 [E0 10 38 F1] W15 T
> S19.2E 11700 H 9750 t V W15 [E0 10 38 F2] W15 t
> S19.2E 99999 H 10600 t V W15 [E0 10 38 F3] W15 T
> S13E 11700 V 9750 t v W15 [E0 10 38 F4] W15 t
> S13E 99999 V 10600 t v W15 [E0 10 38 F5] W15 T
> S13E 11700 H 9750 t V W15 [E0 10 38 F6] W15 t
> S13E 99999 H 10600 t V W15 [E0 10 38 F7] W15 T
>
> Thanks, I had never tried changing the last byte in the codeblock,
> looks quite obviously now.
Ohhh, if your switch only understand voltage- and tone-signals this
should be enough:
S19.2E 11700 V 9750 t v t
S19.2E 99999 V 10600 t v T
S19.2E 11700 H 9750 t V t
S19.2E 99999 H 10600 t V T
S13E 11700 V 9750 t v t
S13E 99999 V 10600 t v T
S13E 11700 H 9750 t V t
S13E 99999 H 10600 t V T
(Not tested, ich have a Diseq 2.0 switch)