Mailing List archive

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[vdr] Re: multiple cards, different diseqc configs



I don't think it is necessary to modify the patch. Try adding the following 
standard diseqc.conf entries for S28.2E and S28.5E to your setup.conf

S28.2E  11700 V  9750  t v W15 [E0 10 38 F0] W15 A W15 t
S28.2E  99999 V 10600  t v W15 [E0 10 38 F1] W15 A W15 T
S28.2E  11700 H  9750  t V W15 [E0 10 38 F2] W15 A W15 t
S28.2E  99999 H 10600  t V W15 [E0 10 38 F3] W15 A W15 T

S28.5E  11700 V  9750  t v W15 [E0 10 38 F0] W15 A W15 t
S28.5E  99999 V 10600  t v W15 [E0 10 38 F1] W15 A W15 T
S28.5E  11700 H  9750  t V W15 [E0 10 38 F2] W15 A W15 t
S28.5E  99999 H 10600  t V W15 [E0 10 38 F3] W15 A W15 T

This will work with a directly connected LNB too. :-)


On Sunday 12 December 2004 22:02, syrius.ml@no-log.org wrote:
> Luca Olivetti <luca@ventoso.org> writes:
> >> I'm pretty sure i saw a patch concerning this limitation, but I can't
> >> find it anymore.
> >
> > http://article.gmane.org/gmane.linux.vdr/14038
>
> I'm already using the sourcecap patch. It doesn't help here.
> SourceCaps = 1 S13.0E S19.2E
> SourceCaps = 2 S28.2E
>
> It's even not possible to modify this patch so that it disables diseqc
> for cards having only one source. In my case I usually use
> SourceCaps = 2 S28.2E S28.5E (yep S28.2E and S28.5E are correctly
> received with one lnb)
>
> Thanks for your quick answer. :)

-- 
Viele Grüße
Christian




Home | Main Index | Thread Index